Both the current input and pressure output range are user-configurable in the field. The converter module uses small parts of minimum mass, which are balanced symmetrically around a pivot point at the center of the mass. This balanced arrangement results in a high performance instrument that reduces sensitivity to vibration. The transducer also provides stable, accurate operation when its output is transmitted to small volume chambers, such as a pneumatic positioner or other pneumatic instrument. Low Pneumatic Supply Consumption—The transducer has low pneumatic supply consumption which lowers operating costs. Split Range—Selectable user field-configurable two-way split range, using either half of the standard input signal.

Author:Arashisar Nikole
Country:Ethiopia
Language:English (Spanish)
Genre:Business
Published (Last):3 February 2014
Pages:476
PDF File Size:19.63 Mb
ePub File Size:19.59 Mb
ISBN:456-9-32245-795-5
Downloads:51750
Price:Free* [*Free Regsitration Required]
Uploader:Sahn



Both the current input and pressure output range are user-configurable in the field. The converter module uses small parts of minimum mass, which are balanced symmetrically around a pivot point at the center of the mass.

This balanced arrangement results in a high performance instrument that reduces sensitivity to vibration. The transducer also provides stable, accurate operation when its output is transmitted to small volume chambers, such as a pneumatic positioner or other pneumatic instrument.

Selectable user field-configurable dip switch setting for output range of 0. The electronics module is encased in a rugged plastic shell which helps to prevent damage to the electronics. The printed wiring board and dip switches are conformal coated to help prevent corrosion.

Converter module coils have corrosion resistant coating and all flexures are gold plated to provide protection from hostile environments. The removable primary orifice and replaceable 5 micrometer filter are easy to remove for service and maintenance.

Open the catalog to page 1 Product Bulletin Figure 2. Fisher i2P Electro-Pneumatic Transducer Mounted on a Rotary Actuator n Easy Maintenance—Modular electronics and converter modules contained in separate housing compartments, isolating the electronics from the process, allow for easy replacement in the field for reduced maintenance time and costs.

Valve Stroking Time Figure 3 shows relative times for loading and exhausting an actuator. Stroking time depends upon the size of the actuator, travel, relay characteristics and Open the catalog to page 2 Product Bulletin Specifications Frequency Response: Gain is attenuated 3 dB at 3 Hz with transducer output signal piped to a typical instrument input Input Signal Available as standard with mA.

User configurable by dip switch for split ranging, see table below. User configurable by Open the catalog to page 4 Product Bulletin Table 1. Table 2. Open the catalog to page 5 Product Bulletin Ordering Information Refer to figure 5 for location of standard mounting holes in the housing. See figures 1 and 2 for typical mounting configurations. Standard mounting hardware is provided for mounting on the actuator, a pipestand, or surface mount. Dimensions are shown in figures 5, 6, 7, and 8.

To determine what ordering information is required, refer to the Specifications table. Carefully review the description of each specification.

Specify the

AMAK - HAYAL PDF

Fisher i2P-100 Instruction Manual

Twitter Emerson introduces i2P electro-pneumatic transducer November 5, - Emerson Process Management introduced the Fisher brand i2P electro-pneumatic transducer to assist oil and gas production facilities in meeting EPA emission control and reporting requirements. The emergent EPA emission rule sets limits for pneumatic controllers installed at well sites and other locations within oil and gas facilities. The controllers are automated instruments used to maintain liquid level, pressure, and temperature of production processes and typically are powered by high-pressure natural gas. The controllers release supply gas including VOCs and methane intermittently with every valve movement or in many cases continuously as part of their normal operation. Electro-pneumatic transducers are instrumental in feeding the operating natural gas medium to the controllers.

A QUEST FOR GODLINESS PACKER PDF

Fisher i2P-100 Electro-Pneumatic Transducer

.

BS 678B PDF

Fisher i2P-100 Manuals & User Guides

.

DIN EN 13480-3 PDF

Fisher I2p-100 Electro Pneumatic Transducer I2P100 Current to Pressure

.

Related Articles